IGS-1042GPA

In stock
SKU:
IGS-1042GPA
Brand: ORing

Industrial 6-port slim type unmanaged Gigabit Ethernet switch with 4x10/100/1000Base-T(X) and 2x100/1000Base-X, SFP socket

 


Enquire Now
Enquire about this product:
  • Provide 4x10/100/1000Base-T(X) and 2x100/1000Base-X SFP ports
  • Supports Jumbo frame up to 9KBytes
  • SFP port support 100Base-FX and 1000Base-X speed
  • Support auto-negotiation and auto-MDI/MDI-X
  • Support store and forward transmission
  • Supports flow control
  • Rigid IP-30 housing design
  • DIN-Rail and wall mounting enabled

This product is listed in Industrial Automation, Mining, Transport
Physical Ports  

10/100/1000Base-T(X) Ports in RJ45 Auto MDI/MDIX

4

100/1000Base-X SFP port

2
Technology  
Ethernet Standards  

IEEE 802.3 for 10Base-T
IEEE 802.3u for 100Base-TX
IEEE 802.3ab for 1000Base-T
IEEE 802.3z for 1000Base-X
IEEE 802.3x for Flow control

MAC Table 1K MAC addressessses
Processing Store-and-Forward
LED Indicators  

Power indicator

Green : Power LED x 2

Fault Indicator

Amber : Indicates PWR1 or PWR2 failure occurred

10/100/1000Base-T(X) RJ45 port indicator 

Green for port Link/Act
Amber for 100Mbps indicator

100/1000Base-X SFP port indicator (P5 ~ P6)

Green for port Link/Act.

SFP Speed DIP-Switch

 

DIP-Switch 1/2

DIP-Switch 1 (ON) and DIP-Switch 2 (ON) : SFP speed setting to 100Mbps
DIP-Switch 1 (OFF) and DIP-Switch 2 (OFF) : SFP speed setting to 1000Mbps

Relay Output DIP-Switch

 

DIP-Switch 1

Power-1 failed warning : (ON) enable, (OFF) disable

DIP-Switch 2

Power-2 failed warning : (ON) enable, (OFF) disable

Fault contact  
Relay

Relay output to carry capacity of 1A at 24VDC

Power  
Redundant Input Power

Dual DC inputs. 12~48VDC on 6-pin terminal block.

Power consumption (Typ.)

6.4 Watts

Overload current protection

Present

Reverse polarity protection

Present

Physical Characteristics

 
Enclosure IP-30
Dimensions (W x D x H)

26.1 (W) x 94.9 (D) x 144.3(H) mm (1.03 x 3.74 x 5.68 inches)

Weight (g)

410 g

Environmental  
Storage Temperature

-40 to 85°C (-40 to 185°F)

Operating Temperature

-40 to 70°C (-40 to 158°F)

Operating Humidity

5% to 95% Non-condensing

Regulatory Approvals  
EMI

FCC Part 15, CISPR (EN55022) class A

EMS

IEC61000-4-2 (ESD), IEC61000-4-3 (RS), IEC61000-4-4 (EFT), IEC61000-4-5 (Surge), IEC61000-4-6 (CS), IEC61000-4-8, IEC61000-4-11

Shock

IEC60068-2-27

Free Fall

IEC60068-2-32

Vibration

IEC60068-2-6

Safety

EN60950-1

Warranty 5 years